Our Projects

Enhancing Structural Integrity with Corbel Addition to Existing Column

Unlocking Structural Excellence: Addressing the Structural Integrity of an Existing Column

In response to structural concerns, our team embarked on a transformative journey to fortify an existing column and slab deemed structurally inadequate. The solution? A strategic addition of corbels on two faces of the column ensures enhanced strength and stability.

Rebar Integration:

Employing precision techniques, we core-drilled and hammer-drilled rebar into the column, establishing a robust framework for the subsequent stages of the repair.

Pour:

The initial pour marked a significant step, introducing structural elements vital to the reinforcement process. This phase laid the groundwork for the comprehensive repair.

Expanding Grout:

Taking the repair to the next level, the incorporated expanding grout is a key component in solidifying the structural enhancements initiated in the first phase.

Final Cement Finishing:

To ensure durability and expose the meticulous repair work, our team executed the final cement finishing with precision. This stage showcased our commitment to not only structural integrity but also aesthetic excellence.

Experience the Unveiling of Structural Excellence: Corbel Addition – Strengthening Foundations, Ensuring Stability.

Elevating Structural Integrity: Reinforcing Columns with Precision

Structural Redemption: Doubling Column Size and Reinforcing with Dywidag® Threadbar

In the face of incorrect reinforcement on two floors, our commitment to structural excellence led to a transformative solution. The columns, found structurally lacking, underwent a substantial enhancement, doubling in size and reinforced with Dywidag threadbar for enduring strength.

Doubling Column Size:

Rectifying the initial structural discrepancies, we doubled the size of the columns, ensuring a robust foundation for the subsequent reinforcement.

Pressurized Formwork Application:

Achieving precision in form and function, pressurized formwork was employed to guarantee a seamless and uniform application of the self-consolidating concrete, further enhancing the structural integrity of the columns.

Dywidag Threadbar Reinforcement:

To fortify the columns, the Dywidag threadbar – synonymous with strength and reliability – was strategically employed, guaranteeing a resilient structure capable of withstanding future challenges.

Finishing Excellence:

Our commitment to excellence extended to the finishing stage, ensuring that the repair not only met but exceeded industry standards, allowing for a visually appealing result in an exposed location.

Self-Consolidating Concrete:

The repair journey continued with the use of self-consolidating concrete, a cutting-edge material chosen for its ability to seamlessly fill intricate spaces and ensure uniform strength distribution.

Unveiling Structural Excellence: Column Reinforcement Beyond Expectations.